Not available

NSM 400

Watch Product Video
SKU#
recQ7qgsyddDNZ68s
DESCRIPTION:

The NSM 400 is the latest innovation in the SOMAG Mount portfolio and a medium-sized device between RSM 400 and OSM 4000. With a mounting space of Ø409 mm, the gyro stabilization platform offers space for antennas, radars and a wide range of sensor systems.

  • Ethernet Interface
  • Power cable length up to 30 m350 Nm peak torque
  • IP 67
  • Paint job according to customer requirements
  • Input of ship data (NMEA frame) or external IMU data (NMEA frame) possible
  • Usable 24/7

  • 360° cameras
  • Thermal imaging cameras
  • Infrared cameras
  • Video cameras
  • Hyperspectral cameras
  • Laser scanners
  • Antennas

Angular Stabilization Ranges

Pitch at 0° Roll: ≤± 20.0°

Roll at 0° Pitch: ≤± 20.0°

Yaw (Drift): no drift correction 

Residual Deviation

≤0.4° rms

Payload2

100 kg | 70 kg | 55 kg

220.5 lbs | 154.3 lbs | 121.3 lbs

Continuous Torque1

25 Nm

Dynamic Peak Torque3

250 Nm

Mass

33 kg | 72.5 lbs

Dimensions

Height: 290 mm | 11.4 in

Diameter:

Ø486 mm | Ø19.1 in

IP Class

IP 67

Operating Temperature

-30 °C … + 55 °C | -22 °F…+131 °F

Storage Temperature

-55 °C … + 85 °C | -67 °F…+185 °F

Communication Interfaces

Ethernet | RS422 | RS232

Operational Voltage

28 VDC (24…30 VDC)

Average Power Consumption at Operational Voltage

90 W

Peak Power Consumptionat Operational Voltage

450 W

Applied Standards

IACS E10, DNV GL, 2006/42/EC Machinery

Preliminary data, subject to change

1 Vehicle motion ≤± 18° / 15°/s / 40°/s2 – small periodical lateral accelerations (≤ 0.5 g) acceptable, constant lateral accelerations for more than 1 minute reduce the performance of the Mount (can be compensated by external GPS input)

2 Possible payload weight depends on lateral acceleration and CoG of payload | shown data is based on 0.9 g lateral acceleration and a CoG payload offset to the Mount surface of: 250 mm (9.8 in) | 400 mm (15.7 in) | 500 mm (19.7 in)

3 Maximum duration 90 s at 55 °C surrounding temperature / longer if temperature inside the unit is < 55 °C

4 Horizontal payload CoG offsets are not considered; without wind force and other possible external forces

No images found.